Kategoriler

Kategoriler

Sepetim

Sepetiniz boş

Toplam:
    • UX90-001 DURUM - OLAY - PALS - PULSE - PULS - KONTAK - ÇALIŞMA SÜRESİ KAYDEDİCİ
    veri-UX90-001

    UX90-001 DURUM - OLAY - PALS - PULSE - PULS - KONTAK - ÇALIŞMA SÜRESİ KAYDEDİCİ

    586,56 TL 
    71,50 TL'den başlayan taksitlerle

    The HOBO State/Pulse/Event/Runtime data logger records state changes,electronic pulses and mechanical or electrical contact closures from external sensing devices. This logger is ideal for monitoring energy consumption, mechanical equipment operation, and water and gas flow. The HOBO UX90-001 State Logger is available in a standard 128 KB memory model (UX90-001) capable of 84,650 measurements and an expanded 512KB memory version (UX90-001M) capable of over 346,795 measurements.

    • One logger with 4 recording modes
    • Internal reed switch can be used to determine when a door or window is open or closed
    • Compatible with a wide range of external sensors
    • Ships with 2.5 mm input cable
    • Compatible with HOBOware and HOBOware Pro software for logger setup, graphing and analysis

    Environment:
    The UX90-001 Data Logger is for use in Indoor environments

    Measurements:
    The UX90-001 Data Logger supports the following measurements:

    Event, Kilowatt Hours (kWh), Motor On/Off, Pulse Input, Runtime, State Open/Closed, Water Flow


    Internal Sensor


    Maximum State, Event, Runtime Frequency: 1 Hz

    Preferred Switch State: No magnet present (normally open)

    External Input


    External Contact Input: Electronic solid state switch closure or logic driven voltage output

    Range: 0 to 3 V DC (USB powered), 0 to 2.5 V DC (battery powered)

    Maximum Pulse Frequency: 50 Hz

    Maximum State, Event, Runtime Frequency: 1 Hz

    Pulse, Event Lockout Time: 0 to 1 second in 100 ms steps

    Solid State Switch Closure: Input Low: < 10 KΩ; Input High: > 500 KΩ

    Internal Weak Pull-Up: 100 KΩ

    Input Impedance: Solid state switch closure: 100 KΩ pull up

    Logger


    Resolution: Pulse: 1 pulse, Runtime: 1 second, State and Event: 1 State or Event

    Logging Rate: 1 second to 18 hours, 12 minutes, 15 seconds

    UX90-001- - Time and Accuracy Specification ChartTime Accuracy: ±1 minute per month at 25°C (77°F) (see Plot A)

    Battery Life: 1 year, typical with logging intervals greater than 1 minute and normally open contacts

    Memory:
    UX90-001: 128 KB (84,650 measurements, maximum)
    UX90-001M: 512 KB (346,795 measurements, maximum)

    Download Type: USB 2.0 interface

    Download Time: 10 seconds for 128 KB; 30 seconds for 512 KB

    Logger Operating Range:
    Logging: -20° to 70°C (-4° to 158°F); 0 to 95% RH (non-condensing)
    Launch/Readout: 0° to 50°C (32° to 122°F) per USB specification

    LCD: LCD is visible from: 0° to 50°C (32° to 122°F); the LCD may react slowly or go blank in temperatures outside this range

    Size: 3.66 x 5.94 x 1.52 cm (1.44 x 2.34 x 0.6 in.)

    Weight: 23 g (0.81 oz)

    Environmental Rating: IP50

    Description: ce - The CE Marking identifies this product as complying with all relevant directives in the European Union (EU)